  Datasheet File OCR Text:
 300W Single Output with PFC Function
Features :
S P V- 3 0 0
series
Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC Fan Built-in fan speed control Fixed switching frequency at 100KHz Output voltage programmable from 20~110% by 1~5.5VDC external control signal 3 years warranty
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE SPV-300-12 12V 25A 0 ~ 25A 300W SPV-300-24 24V 12.5A 0 ~ 12.5A 300W 150mVp-p 20 ~ 26.4V 1.0% 0.2% 0.5% 2500ms, 50ms/115VAC at full load 16ms/115VAC at full load 124 ~ 370VDC PF>0.98/115VAC at full load 85% 86.5% SPV-300-48 48V 6.25A 0 ~ 6.25A 300W 240mVp-p 41 ~ 52.8V 1.0% 0.2% 0.5%
RIPPLE & NOISE (max.) Note.2 150mVp-p 10 ~ 13.2V VOLTAGE TOLERANCE Note.3 1.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) 0.3% 0.5% 800ms, 50ms/230VAC 16ms/230VAC
VOLTAGE RANGE Note.5 88 ~ 264VAC 47 ~ 63Hz FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) 230VAC INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE FUNCTION REMOTE CONTROL OUTPUT VOLTAGE TRIM WORKING TEMP. AC CURRENT (Typ.) 115VAC PF>0.95/230VAC 83.5% 5A 2.5A 20A/115VAC <1mA / 240VAC
40A/230VAC
105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 57.6 ~ 67.2V 13.8 ~ 16.2V 27.6 ~ 32.4V Protection type : Shut down o/p voltage, re-power on to recover 80 5 (TSW1 : detect on heatsink of power transistor) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 4~6VDC power off, <0~0.8VDC power on 4.8 ~ 26.4V 2.4 ~ 13.2V -20 ~ +65 (Refer to output load derating curve) 9.6 ~ 52.8V
20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE HARMONIC CURRENT EMS IMMUNITY ISOLATION RESISTANCE MTBF OTHERS DIMENSION PACKING
NOTE
SAFETY EMC
(Note 4)
UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC / 70% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 207K hrs min. MIL-HDBK-217F (25 ) 215*115*50mm (L*W*H) 1.1Kg; 12pcs/14Kg/0.92CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Mean Well reserves the right to adjust this spec when deemed appropriate. 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:SPV-300-SPEC 2009-07-13
300W Single Output with PFC Function
Mechanical Specification
117.5 32.5 27.5 19 150 177.5
S P V--3 0 0 sseerriie s US P 3 2 0 es 25
Case No. 912G Unit:mm
+V ADJ. 9 8 7 6 5 4 3 4-M4 L=5mm
9.5
36.7
135
95
48.7
8
32.5
2 1
5-M3 L=3mm
5
15 32.5 14 max. 215 150
16
10
37.5
50.5
115
50
Terminal Pin No. Assignment :
25 50
Air flow direction
Pin No. 1 2 3 4
Assignment AC/L AC/N FG RC
Assignment Pin No. PV 5 DC OUTPUT -V 6~7 DC OUTPUT+V 8~9
6-M4 L=5mm
Block Diagram
FAN SPEED CONTROL EMI FILTER ACTIVE INRUSH CURRENT LIMITING POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. FAN
fosc : 100KHz
I/P
RECTIFIERS
+V -V
PV
FG
O.L.P. O.T.P.
PWM & PFC CONTROL
RC
Derating Curve
Static Characteristics
Ta=25
100
100 90
300 250 200 150 100 50 25
80
80 70
60
LOAD (%)
LOAD (%)
0 10 20 30 40 50 60 70 (HORIZONTAL)
40
60 50 40
20
-20
88
90
95
100
115
135
155
175
195
230
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (VAC) 60Hz
File Name:SPV-300-SPEC 2009-07-13
300W Single Output with PFC Function
Function Manual
1.External Voltage Control
Vout 120
S P V--3 0 0 sseerrii e ss USP 225 e
+V -V
+V
OUTPUT VOLTAGE (%)
100
Non-Linear
100
60 40 20 V
OUTPUT CURRENT (%)
-V
LOAD
80
80 60 40 20 V
PV 1~5.5V -V
1
2
3
4
5 5.5 6
20
40
60
80
100 110 120
EXTERNAL VOLTAGE (DC)
OUTPUT VOLTAGE (%)
File Name:SPV-300-SPEC 2009-07-13


▲Up To Search▲   

 
Price & Availability of SPV-300-48

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X